High-resolution black-blood MRI of the carotid vessel wall using phased-array coils at 1.5 and 3 Tesla.

Anumula S, Song HK, Wright AC, Wehrli FW

Department of Radiology, Laboratory for Structural NMR Imaging, University of Pennsylvania Health System, Philadelphia, PA, USA.

RATIONALE AND OBJECTIVES: The aim of this report is to investigate the magnetic field dependence of the signal-to-noise ratio (SNR) for carotid vessel wall magnetic resonance imaging using phased-array (PA) surface coils by comparing images obtained at 1.5 and 3 Tesla (T) and determine the extent to which the improved SNR at the higher field can be traded for improved spatial resolution. MATERIALS AND METHODS: Two pairs of dual-element PA coils were constructed for operation at the two field strengths. The individual elements of each PA were matched to 50 Omega impedance on the neck and tuned at the respective frequencies. The coils were evaluated on a cylindrical phantom positioned with its axis parallel to the main field and the coils placed on either side of the phantom parallel to the sagittal plane. In vivo magnetic resonance images of the carotid arteries were obtained in five subjects at both field strengths with a fast spin-echo double-inversion black-blood pulse sequence with fat saturation. SNR was measured at both field strengths by using standard techniques. RESULTS: At a depth corresponding to the average location of the carotid arteries in the study subjects, mean phantom SNR for the two coils was higher at 3 T by a factor of 2.5. The greater than linear increase is caused by only partial coil loading of these relatively small coils. The practically achievable average SNR gain in vivo was 2.1. The lower in vivo SNR gain is attributed to a reduction in T2 and prolongation of T1 at the higher field strength and, to a lesser extent, the requirement for a decreased refocusing pulse flip angle to operate within specific absorption rate limits. The superior SNR at 3 T appears to provide considerably improved vessel-wall delineation. CONCLUSIONS: Carotid artery vessel-wall magnetic resonance imaging using PA surface coils provides a considerable increase in SNR when field strength is increased from 1.5 to 3 T. This increase can be traded for enhanced in-plane resolution.

Published 2 December 2005 in Acad Radiol, 12(12): 1521-6.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 MRI Research Today. All Rights Reserved.



MRI Research Today Archive:

Volume 1 (2005)
  Issue 1 (April)
  Issue 2 (May)
  Issue 3 (June)
  Issue 4 (July)
  Issue 5 (August)
  Issue 6 (September)
  Issue 7 (October)
  Issue 8 (November)
  Issue 9 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)



MRI Books

MRI Review: Questions and Answers

MRI Review: Questions and Answers