MRI Research - Magnetic Resonance Imaging, Neuroimaging, Brain Tumors

MRI Research Today is a free monthly online journal that collates and summarizes the latest research about MRI, including details on magnetic resonance imaging, neuroimaging, brain tumors.


MRI Research Today

Home

View Latest Issue

Information About MRI

Books on MRI

Advertising in Research Today

View Other Research Today Publications



Assessing arterial blood flow and vessel area variations using real-time zonal phase-contrast MRI.

Oelhafen M, Schwitter J, Kozerke S, Luechinger R, Boesiger P

Institute for Biomedical Engineering, University of Zurich and Swiss Federal Institute of Technology Zurich, Gloriastrasse 35, CH-8092 Zurich, Switzerland.

PURPOSE: To measure peripheral artery function using a real-time phase-contrast (PC)-MRI sequence with tailored image-processing algorithms for flow computation. MATERIALS AND METHODS: An approach to real-time flow measurements was developed based on two-dimensional spatially selective excitation pulses and consecutive tailored processing of the data to derive blood flow and vessel area variations. The data acquisition strategy allows for flow measurements at high spatial and temporal resolutions of 1 mm(2) and 50 msec, respectively. In postprocessing the vessel area is automatically extracted using correlation measures in conjunction with morphological image operators. By means of in vitro and in vivo validations, it is shown that the current methods provide accurate and reproducible measurements of flow and vessel area variations. RESULTS: In vitro the comparison between the lumen area measured with the presented method and the values obtained by caliper gauge measurement showed a difference of 3.4% +/- 3.4% (mean +/- 2 SD). Similarly, the comparison between the stroke volumes determined with the presented method and by stopwatch and bucket measurements yielded a difference of 6.1% +/- 2.1%. In vivo the results from the real-time measurements for lumen area and stroke volume were compared with those from a gated PC-MRI technique with differences of 4.8% +/- 14% and 3.0% +/- 24.7%, respectively. CONCLUSION: The presented method constitutes a reliable tool set for quantifying the variations of blood flow and lumen area in the superficial femoral artery during reactive hyperemia and for studying their correlation with cardiovascular risk factors.

Published 1 March 2006 in J Magn Reson Imaging, 23(3): 422-9.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 MRI Research Today. All Rights Reserved.



MRI Research Today Archive:

Volume 1 (2005)
  Issue 1 (April)
  Issue 2 (May)
  Issue 3 (June)
  Issue 4 (July)
  Issue 5 (August)
  Issue 6 (September)
  Issue 7 (October)
  Issue 8 (November)
  Issue 9 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)



MRI Books

Squire's Fundamentals of Radiology

Squire's Fundamentals of Radiology