Dual gradient-echo MRI of post-contraction changes in skeletal muscle blood volume and oxygenation.

Damon BM, Hornberger JL, Wadington MC, Lansdown DA, Kent-Braun JA

Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee, USA. bruce.damon@vanderbilt.edu

Analysis of post-contraction MRI signal intensity (SI) transients may allow noninvasive studies of microvascular reactivity and blood oxygenation recovery. The purpose of this study was to determine the physiological basis for post-contraction changes in short-echo (6 ms) and long-echo (46 ms) gradient-echo (GRE) MRI signals (S(6) and S(46), respectively). Six healthy subjects were studied with the use of dual GRE MRI and near-infrared spectroscopy (NIRS). S(6), S(46), total hemoglobin concentration ([THb]), and oxyhemoglobin saturation (%HbO(2)) were measured before, during, and after 2 and 8 s dorsiflexion maximal voluntary contractions, and 5 min of proximal arterial occlusion. The changes in S(6) and [THb] after the 2-s contractions were similar to those following 8-s contractions, but changes in %HbO(2) and S(46) were greater following 8-s contractions than after the 2-s contractions. [THb] and S(6) did not change during and following 5 min of arterial occlusion, but %HbO(2) and S(46) were both significantly depressed at similar occlusion durations. Also, distance measures indicated similarity between S(6) and [THb] and between S(46) and %HbO(2). We conclude that following brief human skeletal muscle contractions, changes in S(6) primarily reflect changes in blood volume and changes in S(46) primarily reflect changes in blood oxygenation.

Published 2 April 2007 in Magn Reson Med, 57(4): 670-9.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 MRI Research Today. All Rights Reserved.



MRI Research Today Archive:

Volume 1 (2005)
  Issue 1 (April)
  Issue 2 (May)
  Issue 3 (June)
  Issue 4 (July)
  Issue 5 (August)
  Issue 6 (September)
  Issue 7 (October)
  Issue 8 (November)
  Issue 9 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)



MRI Books

Rad Tech's Guide to MRI: Basic Physics, Instrumentation, and Quality Control (Rad Tech Series)

Rad Tech's Guide to MRI: Basic Physics, Instrumentation, and Quality Control (Rad Tech Series)